siemens bit logic

Bit logic instrunction which have only two state either 1 or 0 (true or false). Just like a button which have only two condition on or off. use of bit logic in industry.The two digits 1 and 0 are called bits. in contacts and coils, 1 called true, energized or activate and 0 indicates false, not activated or not energized. " Each bit logic instrunction have specified bit address".

use of bit logic in industry,start stop motor, machine, condition, monitoring sensors state, solonoid valve command, push button, button logics, trigered next logical function or block etc.


Addressing of bit logic

in bit logic instrunction always use "BOOL data type". size of bool is 1 bits. use foolwing memory area for bit logic


Normally Open Contact

in normal condition this contact act as open contact and no power flow to next instrunction or contact in same network. if Normally Open Contact set to 1 it will energized and act as close contact so power begains to flow through it and go to next instrunction.

first example address of Normally open contact I0.0 and address of output coil is Q0.0 . normal condition Q0.0 is 0(false) because no power flow through I0.0. if I0.0 is set to 1(true) then output coil is set to 1.


Normally Closed Contact

in normal condition Normally Closed contact act as Closed contact and power flow throught it. if Normally Closed Contact set to 1 it will act as open contact so no power flow through it.

first example address of Normally Closed contact is I0.0 and address of output coil is Q0.0 . in normally state of Q0.0 is 1(true) because power flow through Normally Closed contact I0.0. if I0.0 is set to 1(true) then output coil is set to 0. considered next example in this logic use three Normally Closed contact,


Output Coil

output coil always use for output. state of output coil is depended on previous state of logic. in following example state of output bit move to memory bit


Midline Output

--( # )---,The midline output element saves the logical result of the preceding branch elements. Midline Output is an intermediate assigning element which saves power flow status to a specified address. midline output In series with other contacts , midline output is inserted like a contact.A midline output element may never be connected to the power rail or directly after a branch connection or at the end of a branch.


Invert Power Flow

-|NOT|- invert output of preceding branch elements bits. it is work as NOT gate. -|NOT|- invert result of logic operation not affect memory area directely. considered folowing example


set reset flip flop block

SR (Set-Reset Flip Flop) set or reset bit of the specified address. if input of set S is "1" , and "0" at the Reset R input then bit set to defined address. Otherwise, if the signal state is "0" at the S and "1" at the R input, the flip flop is reset. If "1" at both inputs, the order is of primary importance. The SR flip flop executes first the set instruction then the reset instruction at the specified address, so that this address remains reset for the remainder of program scanning. note: The S (Set) and R (Reset) instructions are executed only when the input is "1". when input "0" has no effect on these instructions and the address specified in the instruction remains unchanged.use when set and reset bit on address


reset set flip flop block

RS (Reset-Set Flip Flop) is reset specified address if the signal state is "1" at the R input, and "0" at the S input. Otherwise, if the signal state is "0" at the R input and "1" at the S input, the flip flop is set. If "1" at both inputs, the order is of primary importance. The RS flip flop executes first the reset instruction then the set instruction at the specified address, so that this address remains set for the remainder of program scanning.


Set reset coil

Set and reset Coil are executed only if preceding instructions is "1" (power flows to the coil). both coil are output type coil. in step7 not allowed to use both coil in same line or series with each other.